Volume 17, number 1
 Views: (Visited 364 times, 1 visits today)    PDF Downloads: 697

Al-Quwaie D. A. H. Extracorporeal Circuit Device for Camel Antibodies Production from Blood Using Magnetic Nanoparticles. Biosci Biotech Res Asia 2020;17(1).
Manuscript received on : 29-Nov-2019
Manuscript accepted on : 18-Mar-2020
Published online on:  01-04-2020

Plagiarism Check: Yes

Reviewed by: Kanti Shrestha orcid

Second Review by: Shafiul kadir orcid publons

Final Approval by: Dr. Susana orcid publons

How to Cite    |   Publication History    |   PlumX Article Matrix

Extracorporeal Circuit Device for Camel Antibodies Production from Blood Using Magnetic Nanoparticles

Diana A. H. Al-Quwaie

Department of Biological Sciences, Rabigh College of Science and Arts, King Abdulaziz University (KAU), Rabigh, Saudi Arabia

Corresponding Author E-mail :dalquwaie@kau.edu.sa

DOI : http://dx.doi.org/10.13005/bbra/2817

ABSTRACT: The present work describes the use of nanotechnology in the direct purification of antibodies from life camels. The new method relies on the use of a simple extracorporeal device coupled with affinity purification to antigen functionalized magnetic nanoparticles that is applied continuously in extracorporeal circuit. The device was connected to camel blood stream by HLS cannulae veno-venous to allow the blood stream path through the device with the flow rate of ~ 10 ml/min. The new method requires no sacrificing the animal for the recovery of antibodies. Antigen functionalized magnetic nanoparticles are injected into a blood flow where they capture the targeted antibodies by affinity binding. Subsequent removal of the antibody-loaded nanomagnets from the bloodstream takes place by continuous magnetic separation allowing recirculation of the blood for continuous production of more antibodies. For the demonstration of the possible use of this new method in purifying the antibodies from immunized camels, lysozyme was used as the antigen for immunization and magnetic nanoparticles functionalization. Immunization of camels was performed for a period of eight-week with gradual increase of antigen amount up to 5 or 1 mg antigen. The device was validated via Sandwich ELISA and results indicated the efficacy of the new device in the continuous recovery of camelid antibodies without the need to sacrifice the animal and the need to use antigen at no more than 1 mg for successful antibodies production using the new device at a large scale.

KEYWORDS: Camelid; Lysozyme; Nanomagnet; Recirculation

Download this article as: 
Copy the following to cite this article:

Al-Quwaie D. A. H. Extracorporeal Circuit Device for Camel Antibodies Production from Blood Using Magnetic Nanoparticles. Biosci Biotech Res Asia 2020;17(1).

Copy the following to cite this URL:

Al-Quwaie D. A. H. Extracorporeal Circuit Device for Camel Antibodies Production from Blood Using Magnetic Nanoparticles. Biosci Biotech Res Asia 2020;17(1). Available from: https://bit.ly/3bzdFY6

Introduction

Hetero-tetrameric antibodies of mammalian immunoglobulin (IgG) comprise two domains of heavy (H) and two domains of light (L) identical extremely conserved sequence of amino acids in the resulted polypeptide chains (Padlan, 1994). This immunoglobulin structure is called IgG1. Sera of Camelidae comprise two additional types of IgG antibodies namely IgG2 and IgG3. These camelid antibodies lack the L chain polypeptide domains and is made of three, not four, domains as they do not contain the first constant domain (CH1). The homo-dimeric protein of the H chain harbors the variable domain VHH at the N terminal (Muyldermans et al., 2009), which is adapted to function in antigen binding due to the lack of variable light chain domain (VL) (Muyldermans et al., 1994; Vu et al., 1997; Harmsen et al., 2001; Maass et al., 2007). VHH is known to contain an additional disulfide bond (Cys-Cys) (Conrath et al., 2003) that participates in making the loop structure (Muyldermans et al., 2001; Genst et al., 2006). Overall structure of the camelid IgG as compared to clasical IgG is shown in Figure 1.

Magnetic nanoparticles were used in various medical, diagnostic and industrial applications (Masashige, 2002). Coupling of the proteinaceous sources, such as antigen, at the surface of magnetic nanoparticles was achieved by several methods using surface activating material and surface functionalized magnetic particles (Pankhurst et al., 2003). By the use of this new approach, blood purification system includes filtering antibodies rather than filtering cut-offs or column surface saturation.

The present study describes a magnetic separation-based antibody purification system from camel blood using ultra-strong magnetic nanoparticles to be attached to an extracorporeal blood purification circuit for continuous production of the camelid antibodies without the need to sacrifice the animal.

 Figure 1: Structure of camelid IgG as compared with the classical IgG. IgG = immunoglobulin, CH = constant heavy chain domain, VH = variable heavy chain domain, CL = constant light chain domain, VL = constant light chain domain, VHH = variable domain of the heavy chain homodimer. Figure 1: Structure of camelid IgG as compared with the classical IgG. IgG = immunoglobulin

Click here to View Figure

Materials and Methods

Camel Immunization

Three premature male camels were utilized in the present study. The first was continuously injected with 0.1, 0.5, 1, then 5 mg lysozyme (antigen), while the second was injected with 0.1, 0.2, 0.5, then 1 mg lysozyme. Antigen dose was increased biweekly across the eight-week experiment period. The third animal was injected with wash buffer (negative control) (cat. no. K0001.C.100) of the Lysozyme ELISA kit (Eagle Biosciences, Inc.). Blood samples were taken after eight weeks in order to detect the dynamics of utilizing this device across two concentrations of antigen.

Antigen Immobilization of Magnetic Nanoparticles

Coupling and blocking of magnetic nanoparticles and protein complex were done using PierceTM NHS-activated magnetic nanoparticles (Thermo Scientific) following the manufacturer’s manual. Magnetic nanoparticles were first washed with buffer A, then 5 mg of NHS-activated magnetic nanoparticles were coupled with 10 mg protein (antigen), then, 200 ul protein solution mixed with washed magnetic nanoparticles were incubated at RT for 6 hours, then, washed with wash buffer B and water. The reaction was terminated by washing with quenching buffer several times and antigen immobilized nonoparticles were reconstituted in 1 ml PBS buffer and stored at 4ºC until further usage.

Device Construction and Purification of Camel’s Antibodies

Antigen functionalized magnetic nanoparticles were dispersed in 300 ml hydroxyl ethyl starch 6%, then added to magnetic-particles-supply reservoir. Then, the device was attached to the immunized animals (10 ml/min flow rate). The device was constructed from the cannula injected to venous allowing blood stream to flow inside the tubes and the antigen functionalized magnetic particles solution to be mixed with camel’s blood. Then, nanomagnets with antigen-antibody complex were pumped out to the magnetic separator tube for nanoparticles removal to allow clean blood to get back to the venous. Collected magnetic nanoparticles were washed in PBS (pH 7.0) three times to remove magnetic nanoparticles, then, antibodies (Abs) were eluted using 0.1 glycine-HCL (pH 2.3) buffer and dialyzed five times against PBS (pH 7.0) buffer. Protein (e.g., antibodies) concentration was determined using the standard BCA protein assay kit (Pierce, IL, USA).

Sandwich Elisa

Lysozyme camelid antibodies were detected using the Lysozyme Sandwich Enzyme-Linked Immunosorbent (ELISA) kit (Eagle Biosciences, Inc.). The assay was done following user’s manual except for the use of the ELISA microtiter PVC plates coated with the newly recovered camelid capture Abs (10 μg/ml) in carbonate/bicarbonate buffer (pH 9.6) instead of the use of plates pre-coated with anti-human lysozyme capture Abs supplied with the kit. Plates were covered with adhesive and incubated at 4°C overnight. Then, coating solution was cleared, and plates were washed twice by filling wells with PBS (200 μl). Then, the plates were left to dry. The uncoated protein-binding sites were blocked in the coated wells by the use of 200 μl blocking buffer (5% non-fat dry milk/PBS/well) overnight then buffer was removed and again plates were left to dry for subsequent use.

Sandwich ELISA included the device-recovered Abs (200 ul at 10 ug/ml) used as the capture Abs, lysozyme (originally used for generating the camelid Abs), used as the antigen, and the indicator system of horseradish peroxidase (HRP)-conjugated rabbit used as the secondary detection anti-lysozyme Abs. A standard curve was prepared by plotting lysozyme antigen at known concentrations against the obtained readout at optical density 450 nm using 800™ TS Absorbance Readers. The Linear plot model was used to present the concentration of lysozyme in one axis and the readout in the other axis. R2 values are used to determine fitting, with values higher than 0.99. Concentration of the antigen was detected from the standard curve as indicated in the user manual. Experiment was done in three replicates and statistically analyzed using paired comparison of t test at a = 0.05 for the two antigen-injected animals.

Results and Discussion

Pierce™ N-hydroxysuccinimide (NHS)-activated magnetic nanoparticles (Thermo Scientific) were used to covalently immobilize (functionalize) lysozyme protein for the affinity purification of camelid antibodies. The activated magnetic nanoparticles contain NHS functional groups reacting with primary amines on the protein in order to construct a stable amide linkage. Coupling reaction was performed in amine-free buffer (pH 7-9) and nanoparticles were removed from the reaction using a magnetic stand.

As shown in Figure 2, the work presents a new device for real-time purification of specific antibody from large animal to increase productivity without the need to sacrifice it. The figure indicates antigen functionalized magnetic nanoparticles that are injected continuously into blood flow where the required Abs are specifically captured by affinity binding. Removal of the antibody-loaded nanomagnets from bloodstream takes place by magnetic separation allowing recirculation of the blood for continuous production of more Abs. Cleaning bloodstream from the Abs avoids the occurrence of blood coagulation and allows the continuous supply of Abs from alive animal without the need to sacrifice it.

  Figure 2: Schematic representation of the extracorporeal circuit device used for continuous production of camelid antibodies Figure 2: Schematic representation of the extracorporeal circuit device used for continuous production of camelid antibodies

Click here to View Figure

Sandwich ELISA is a sensitive and robust assay that was used in the present study in order to detect the quality and quantity of the recovered camelid Abs using the new wearable device. During this enzyme assay, antigen is sandwiched between two layers of antibodies, namely capture and detection Abs (Figure 3).

 Figure 3: Sandwich ELISA system for the detection of lysozyme bound to the newly recovered camelid Ab (capture Abs) in one or more epitopes and to the HRP-conjugated rabbit Abs (detection Abs) in other epitopes. Figure 3: Sandwich ELISA system for the detection of lysozyme bound to the newly recovered camelid

Click here to View Figure

The assay basically detects presence and quantity of antigen between these two layers of Abs. Capture Abs represent the new camelid Abs, while the detection Abs represent the manufacturer’s Abs. The latter is part of the indicator system of Abs with HRP-conjugate that directly indicates the intensity of the antigen (lysozyme) by which detection Abs bind to, while indirectly report the intensity and affinity of the capture camelid Abs, the focus of the present study. It was expected that camelid Abs will react with one or more epitopes on the antigen that are completely different from the epitopes on the same antigen that react with the rabbit Abs. This speculation was based on the difference in structure of the two types of Abs shown in Figure 1.

Sandwich ELISA can be a direct or indirect method of detection. In direct method, antigen can be detected by both capture and detection Abs, while indirect method, as in the present case, secondary Abs are used to detect antigen immobilized by capture Abs. As monoclonal capture Abs recognize a single epitope, polyclonal capture Abs often bind to several epitopes, thus pull down as much antigen as possible. Accordingly, a binding curve is constructed based on the affinity of the detection Abs that directly reflects antigen concentration and indirectly reflects capture Abs concentration and affinity.

The first incubation step of sandwich ELISA in the current study involved binding of lysozyme to the capture camelid Abs coated with PBS on the PVC plate. Unbound antigen was removed by washing to allow secondary Abs linked to HRP enzyme to further bind only to the antigen captured by camelid Abs to form a sandwich of “capture Abs-lysozyme-detection Abs”. By doing this, antigen served as a bridge between both types of Abs. The secondary Abs are conjugated with peroxidase that constitutes the indicator system. Then, addition of the colorless tetramethylbenzidine or TMB, a peroxidase substrate, resulted in the production of blue-colored TMB diimine with intensity respective to proportion to the amount of analyte (antigen) present. After adding the acidic stop solution (sulfuric acid), enzymatic reaction is terminated and color changes from blue to yellow (Figure 3). The intensity of the yellow color is indirectly proportional to concentration of antigen, e.g., lysozyme, thus, intensity of capture Abs. TMB is a hydrogen donor used for hydrogen peroxide reduction by HRP to water. The recovered diimine gives the solution a blue color, and the intensity of blue color is read on a spectrophotometer at the wavelengths of 370 nm. The reaction is halted by addition of acid (sulfuric acid) as a stop reagent to turn TMB’s color from blue to yellow at 450 nm (Martin et al., 1984).

The results of lysozyme concentrations across time for the three camels are shown in Table 1. The results of calculated lysozyme concentration indicated that the amount of 1 mg lysozyme is not significantly different from that of 5 mg (P=0.253). This data indicates that 1 mg lysozyme is sufficient to recover appropriate amounts of the camelid Abs and no higher concentration of the Abs is required. The reason for considering the least concentration of the antigen is to avoid the chance of blood coagulation when using high concentration across time. The overall results indicated that the new device is effective in recovering camelid Abs from alive camels without the need to sacrifice it.

Table 1: Lysozyme concentrations calculated from linear logarithmic abscissa for three camels based on the intensity of the yellow color of substrate (TMB) resulted from the HRP enzyme conjugated to secondary Abs of sandwich ELISA “capture Abs-lysozyme-detection Abs”. Original amounts of lysozyme at week 8 for the three camels were 5, 1 and 0 (control) mg.

Camel Original lysozyme injected (mg) Calculated lysozyme conc. (ng/ml)
1 5 635.41
2 1 547.36
3 0 0.79

New technical approaches into dangerous diseases (ex., autoimmune disorders) towards the identification of new therapeutic targets requires the use of new blood purification techniques (Bellomo et al., 2001; Tetta et al., 2003; Zang et al., 2014; Liu et al., 2017). Regardless of the current blood purification systems, target-specific filtering of multiple compounds is still a major task, particularly for molecules differing in physicochemical character with high molecular weight compounds (e.g., proteins). As diffusion is slow and filtration is inappropriate due to filter cut-offs, patients requiring exchange of centrifugal plasma or blood purification through adsorbents. Nonetheless, antibody-coated adsorbents (Du Moulin et al., 1993) or microsphere-based detoxification systems (MDS) (von Appen et al., 1996; Weber et al., 2001) are currently being introduced to specifically aim at therapeutic targets. Spherical nonporous particles used as adsorbents was shown to take advantage from the intrinsically better surface accessibility due to the higher external surface areas and the shorter diffusion distances as compared to membranes (Herrmann et al., 2009). Herrmann et al. (2010) described the appraoch of magnetic blood purification system using target-specific metal nanomagnets to get red of toxins from blood more efficiently. The latter approach of toxin purification is analogue to that adopted in of the present work.

Through the present work, the developed small device can be easily attached externally in the camel’s body in order to extract specific antibodies from circulating blood without the need to sacrifice the animal. This device provides a simple, safe, cost-effective and time-saving method for appropriate antibodies production and purification from camels at large scale.

Acknowledgment

The author acknowledge Dr. Ahmed bahieldin for helping in revising the scientific idea and supervising the manuscript writing process

Funding Source

Self-funded

Conflict of Interest

The author declares, no conflict of interest.

References

  1. Bellomo, R., Baldwin, I., Ronco, C. (2001): Extracorporeal blood purification therapy for sepsis and systemic inflammation: its biological rationale. In: Ronco, C., Bellomo, R., La Greca, G., eds., Blood Purification in Intensive Care. Basel, Switzerland, Karger 132: 367-374.
    CrossRef
  2. Conrath, K. E., Wernery, U., Muyldermans, S., Nguyen, V. K. (2003): Emergence and evolution of functional heavy-chain antibodies in Camelidae, Develop. Comp. Immunol. 27: 87-103.
    CrossRef
  3. De Genst, E., Silence, K., Decanniere, K., et al. (2006): Molecular basis for the preferential cleft recognition by dromedary heavy-chain antibodies. Proc. Natl. Acad. Sci. USA 103: 4586-4591.
    CrossRef
  4. Du Moulin, A., Müller-Derlich, J., Bieber, F., et al. (1993): Antibody-based immunoadsorption as a therapeutic means. Blood Purif. 11: 145-149.
    CrossRef
  5. Fang, H., Huang, J., Ding, L., et al. (2007). Preparation of magnetic chitosan nanoparticles and immobilization of laccase. J. Wuhan Univ. Technol-Mater 24: 42-47.
    CrossRef
  6. Harmsen, M. M., Ruuls, R. C., Nijman, I. J., et al. (2001): Llama heavy chain V-regions consist of at least four distinct subfamilies revealing novel sequence features. Mol. Immunol. 37: 579-590.
    CrossRef
  7. Herrmann, I. K., Grass, R. N., Stark, W. J. (2009): High-strength metal nanomagnets for diagnostics and medicine: carbon shells allow long-term stability and reliable linker chemistry. Nanomedicine 4: 787-798.
    CrossRef
  8. Herrmann, I. K., Urner, M., Koehler, F. M., et al. (2010): Blood purification using functionalized core/shell nanomagnets. Small 6: 1388-1392.
    CrossRef
  9. Liu, E., Zheng, X., Xu, X., et al. (2017): Preparation of diethylenetriamine-modified magnetic chitosan nanoparticles for adsorption of rare-earth metal ions. New J. Chem. 41: 7739-7750.
    CrossRef
  10. Maass, D. R., Sepulveda, J., Pernthaner, A., Shoemaker C. B. (2007): Alpaca (Lama pacos) as a convenient source of recombinant camelid heavy chain antibodies (VHHs). J. Immunol. Methods 324: 13-25.
    CrossRef
  11. Martin, T. L., Mufson, E. J., Mesulam, M. M. (1984): The light side of horseradish peroxidase histochemistry. J. Histochem. Cytochem. 32: 793.
    CrossRef
  12. Masashige, S. (2002): Functional magnetic particles for medical application. Biosci. Bioengin. 94: 606-613.
    CrossRef
  13. Muyldermans, S., Atarhouch, T., Saldanha, J., et al. (1994): Sequence and structure of VH domain from naturally occurring camel heavy chain immunoglobulins lacking light chains. Protein Eng. 7: 1129-1135.
    CrossRef
  14. Muyldermans, S., Baral, T. N., Cortez Retamozzo, V., et al. (2009): Camelid immunoglobulins and nanobody technology. Vet. Immunol. Immunopathol. 128: 178-183.
    CrossRef
  15. Muyldermans, S., Cambillau, C., Wyns, L. (2001): Recognition of antigens by single-domain antibody fragments: the superfluous luxury of paired domains. TIBS 26: 230-235.
    CrossRef
  16. Nguyen, V. K., Desmyter, A., Muyldermans, S. (2001): Functional heavy-chain antibodies in Camelidae. Adv. Immunol. 79: 261-296.
    CrossRef
  17. Padlan, E. A. (1994): Anatomy of the antibody molecule. Mol. Immunol. 31: 169-217.
    CrossRef
  18. Pankhurst, Q. A., Connolly, J., Jones, S. K., Dobson, J. (2003): Applications of magnetic nanoparticles in biomedicine. J. Phy. D Appl. Phys 36: R167-R181.
    CrossRef
  19. Roca, A. G., Costo, R., Rebolledo, A. F., et al. (2009): Progress in the preparation of magnetic nanoparticles for applications in biomedicine. J. Phys. D Phys. 42: 1-11.
    CrossRef
  20. Tetta, C., Bellomo, R., D’Intini, V., et al. (2003): Do circulating cytokines really matter in sepsis? Kidney Int. 63: S71.
    CrossRef
  21. Von Appen, K., Weber, C., Losert, U., et al. (1996): Microspheres based detoxification system: a new method in convective blood purification. Artif. Organs 20: 420-425.
    CrossRef
  22. Vu, K. B., Ghahroudi, M. A., Wyns, L., Muyldermans, S. (1997): Comparison of llama VH sequences from conventional and heavy chain antibodies, Mol. Immunol. 34: 1121-1131.
    CrossRef
  23. Weber, V., Weigert, S., Sára, M., et al. (2001): Development of affinity microparticles for extracorporeal blood purification based on crystalline bacterial cell surface proteins. Ther. Apher. Dial. 5: 433-438.
    CrossRef
  24. Zang, L., Qiu, J., Wu, X., et al. (2014): Preparation of magnetic chitosan nanoparticles as support for cellulase immobilization. Ind. Eng. Chem. Res. 53: 3448-345
    CrossRef
(Visited 364 times, 1 visits today)

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.