Volume 7, number 1
 PDF Downloads: 1339

HPLC Method Development for Testosterone Cipionate in Bulk Drug and Oil-Based Injectables

Rakesh Kumar Gupta1, R.K. Roy1, Anurag1 and A.N. Jha2

1Dr.K.N.Modi Institute of Pharmaceutical Education and Research, Modi Nagar (India). 2Belco Pharma. , Bahadurgarh (India).

ABSTRACT: Isocratic liquid chromatographic method for the determination of testosterone cipionate (TC) in bulk drug and oil-based injectables have been developed and validated. Mobile phase methanol: water (90:10) was used for Testosterone Cipionate. For this method , a bonded-silica Luna 5μ C8 (2)100A (250 mm ª 4.6 mm, C 8, 5 micron.) (250C) column, a flow-rate of 1.2 ml min”1 and UV absorbance detection at 240 nm were used and separations up to base line were achieved. Prior to HPLC analysis, different dilution of bulk drug and sample preparation was required from oil-based injectables using the surfactant sodium dodecyl sulphate.

KEYWORDS:

HPLC; Validation; Testosterone cipionate; Oil-based injectables

Download this article as: 
Copy the following to cite this article:

Gupta R. K, Roy R. K, Anurag, Jha A. N, HPLC Method Development for Testosterone Cipionate in Bulk Drug and Oil-Based Injectables. Biosci Biotech Res Asia 2010;7(1)

Copy the following to cite this URL:

Gupta R. K, Roy R. K, Anurag, Jha A. N, HPLC Method Development for Testosterone Cipionate in Bulk Drug and Oil-Based Injectables. Biosci Biotech Res Asia 2010;7(1). Available from: https://www.biotech-asia.org/?p=9798

[ HTML Full Text]

Back to TOC